LIGHTING
 
Control - Circuits - Lighting Positions - Color - House Plot - Power
 
CONTROL
 
An ETC ION (with 2x20 Fader Wing) is located in a booth at the rear of the balcony level.
A remote focus unit is available for set-ups.

Winches for the lighting bridge and the upstage electric can be activated only from the stage manager's console backstage.

Auditorium house lights can be controlled from both the lighting console and the stage manager's console.

192 ETC Sensor dimmers. (Dimmer Per Circuit)


CIRCUITS
 
Stage circuits are 20-amp, 115 volt.

Stage connectors are 20-amp twist-lock.

Adaptors are available for converting to pin block or Edison connectors.


LIGHTING POSITIONS
 
Instruments in soffit are in a fixed position.

There is a bridge position and an upstage electric, both of which are motorized.

Two 30-foot towers are located just behind the proscenium on both sides of the stage for side lighting.

4- 8’ tall movable trees are available. Each tree contains 2 lighting instruments (Altman Shakespeare’s 40’).  1 additional light may be added though lights from the rig will have to be removed to accommodate. Dimmer Per Circuit.

A drivable manlift capable of extending 20 feet high is available for focusing instruments on stage.


COLOR
 
An ample supply of Lee and Roscolux colors are stocked.


FX
 
1-Martin Magnum Hazer / Smoke Machine located off Stage Right
POWER: Circuit 153


STANDARD HOUSE PLOT
 

STANDARD HOUSE PLOT

The standard lighting plot consists of:

FOH

4- Front Washes (8- Altman Shakespeare’s 20’ comprise each wash)

1-FOH Gobo Stage Wash (2- Altman Shakespeare’s 40’ comprise the wash)

12-FOH Specials (Altman Shakespeare’s 40’)

STAGE

3-Down Light Washes over stage (6- ETC S4 50’ comprise each wash)

1-Down Light Wash Sea Changer Colour Changing Units (6- ETC S4 50’ comprise the wash)

2- High Side Washes (6- Altman Shakespeare’s 40’ comprise each wash)

1-On Stage Gobo Wash (4- Altman Shakespeare’s 40’ comprise the wash)

3-Colour CYC WASH Strand Coda Cyc Cells (500w)

2- Stark Lite Model 1271 1200w HMI Follow Spots are located in the rear soffit.

PLEASE SEE PLOT & MAGIC SHEET FOR ADDITIONAL STAGE LIGHTING & SPECIALS

Beckman House Plot
beckman_house_venue.pdf

Beckman Light Plot Stage
beckman_light_plot_stage.pdf

Beckman FOH Light Plot
beckman_foh_guest_plot.pdf

Beckman Magic Sheet
beckman_magic_sheet.pdf

Get Acrobat Reader


POWER SUPPLY
 
A direct feed from the building's power supply is available if needed, consisting of,
  • 1 ea. 3 phase 5 wire 100-amp 120/208v Disconnect Panel with CamLoc's - approx. 50 feet from stage left.
  • 1 ea. 3 phase 5 wire 200-amp 120/208v Disconnect Panel with CamLoc's - approx. 55 feet from stage left.
  • 1 ea. 50-amp Disconnect Panel with 250v Twist Lock - approx 55 feet from stage left.
  • 1 50-amp 250v Portable power panel with 12 individual 20-amp Edison circuits, with 100 feet of feeder cable.
For lighting accommodations and questions, contact Derrick McDaniel at:
(626) 395-1346 - dcmcdani@caltech.edu

For special electrical accommodations and questions, contact Dwayne Miles at:
(626) 395-3839 or drmiles@caltech.edu


HOME